In a surprising discovery, researchers from Germany have found that whole-body staging of patients with recently diagnosed malignant melanoma using either MRI or PET/CT could miss a substantial number of metastatic lesions.
Bone metastasis in 43-year-old patient with NSCLC detected with whole-body MRI and whole-body FDG-PET/CT. (Provided by G. Antoch and F. Vogt)
In a surprising discovery, researchers from Germany have found that whole-body staging of patients with recently diagnosed malignant melanoma using either MRI or PET/CT could miss a substantial number of metastatic lesions.More than 50,000 U.S. patients will be diagnosed each year with melanoma, according to the National Cancer Institute. The disease is usually confined within a skin lesion but can spread through the body during advanced stages. Good prognosis depends on accurate tumor staging, which is done with CT, MRI, ultrasound, or scintigraphy. The whole-body exam has recently been recognized as the most accurate for staging. Radiologists must be aware, however, that regional or lymph node metastases could appear within a few months of the resection of a melanoma, and they cannot trust blindly in the primary imaging performed immediately after surgery, said Dr. Florian Vogt from the department of diagnostic and interventional radiology at the University Hospital of Essen. "You should always scan these patients at least a couple of times within one year of the primary staging. There might be future metastases, so these patients need long-term follow-up," Vogt said in an interview with Diagnostic Imaging.Vogt and colleagues enrolled 60 consecutive patients who underwent whole-body 1.5T MRI and whole-body FDG-PET/CT for staging of regional lymph nodes (N) and distant (M) metastases after primary tumor resection. The investigators followed the American Joint Committee on Cancer Staging guidelines for tumor classification and used biopsy and clinical follow-up as gold standards. Two radiologists interpreted MR images, while PET/CT scans were read by one radiologist and one nuclear physician. Fifty-six patients completed the mean follow-up of 748 days. The researchers found that a significant number of patients initially staged as N-negative and M-negative with whole-body MRI and whole-body PET/CT eventually proved to have undetected regional or distant metastases. Whole-body MRI and whole-body PET/CT determined regional lymph node involvement correctly in 46 and 48 cases, respectively. N-staging with whole-body MRI yielded a specificity of 100% but a sensitivity of only 23%. Regional lymph node staging with whole-body PET/CT fared only slightly better with specificity and sensitivity values of 100% and 38.5 %, respectively. The M-stage was diagnosed correctly in 42 patients with whole-body MRI and in 46 with PET/CT. Of 56 patients who underwent staging for distant metastases with PET/CT, three were confirmed as false positives and seven turned into false negatives (sensitivity, 41.7 % and specificity, 93.2 %). With whole-body MRI, the M-stage yielded three false positives and 11 false negatives (sensitivity, 15.4% and specificity, 93 %). Another research team from Essen also evaluated the accuracy of whole-body FDG-PET/CT and whole-body MRI for staging and detection of bone metastases in patients with a recent diagnosis of melanoma and non-small cell lung cancer.Dr. Gerald Antoch and colleagues assessed 109 patients, 55 with melanoma and 54 with NSCLC. Patients underwent whole-body staging with contrast-enhanced FDG-PET/CT. Patients also underwent nonenhanced T1/T2 and contrast-enhanced T1-weighted whole-body MRI within a mean time interval of 0.6 days of a PET/CT scan. A nuclear medicine physician and a radiologist read PET/CT and MRI studies, respectively, in a blinded fashion. Researchers also used histopathology and clinical follow-up (mean = 434 days) as the standards of reference. The investigators found whole-body PET/CT and whole-body MRI similarly accurate for staging and detection of bone metastases. They also observed a significant rate of false negatives, however, particularly with whole-body MRI, although the difference was not statistically significant when compared with whole-body PET/CT, Antoch said."There is a substantial number of false-negative findings if you perform the two imaging procedures at diagnosis of the patient. That really requires a close follow-up of these patients," Antoch said.The papers require validation by larger population studies, investigators said.For more online information, visit Diagnostic Imaging's RSNA Webcast.
Can Generative AI Facilitate Simulated Contrast Enhancement for Prostate MRI?
January 14th 2025Deep learning synthesis of contrast-enhanced MRI from non-contrast prostate MRI sequences provided an average multiscale structural similarity index of 70 percent with actual contrast-enhanced prostate MRI in external validation testing from newly published research.
Can MRI Have an Impact with Fertility-Sparing Treatments for Endometrial and Cervical Cancers?
January 9th 2025In a literature review that includes insights from recently issued guidelines from multiple European medical societies, researchers discuss the role of magnetic resonance imaging (MRI) in facilitating appropriate patient selection for fertility-sparing treatments to address early-stage endometrial and cervical cancer.
Surveillance Breast MRI Associated with Lower Risks of Advanced Second Breast Cancers
January 8th 2025After propensity score matching in a study of over 3,000 women with a personal history of breast cancer, researchers found that surveillance breast MRI facilitated a 59 percent lower risk in advanced presentations of second breast cancers.
New Survey Explores Radiologist and Neurologist Comfort Level with AI Triage for Brain MRI
January 7th 2025Survey results revealed that 71 percent of clinicians preferred adjunctive AI in facilitating triage of brain MRI scans and 58 percent were comfortable utilizing AI triage without input from radiologists.