PET/CT is significantly more accurate than CT alone, PET alone, and side-by-side CT and PET when assessing the TNM stage of different malignant diseases. This diagnostic advantage translates into treatment plan changes in a substantial number of patients, according to Dr. Gerald Antoch and colleagues at University Hospital Essen in Germany.
PET/CT is significantly more accurate than CT alone, PET alone, and side-by-side CT and PET when assessing the TNM stage of different malignant diseases. This diagnostic advantage translates into treatment plan changes in a substantial number of patients, according to Dr. Gerald Antoch and colleagues at University Hospital Essen in Germany.
Researchers viewed scans from 260 consecutive patients (167 female) with different oncological diseases who had undergone FDG-PET/CT for tumor staging. One hundred twelve patients were imaged for primary tumor staging and 148 for suspected recurrent disease.
The majority of patients had malignant non-small cell lung carcinoma, followed by head and neck tumors, gastrointestinal tumors, and others.
PET/CT imaging was performed on a Siemens Biograph scanner with an axial field-of-view from head to upper thigh. Investigators used IV contrast CT for diagnostic data.
Two nuclear medicine specialists viewed the PET alone images. They evaluated the images first qualitatively by the areas of increase glucose metabolism, then quantitatively by the standard uptake value (SUV).
An SUV cutoff value for malignancy of 2.5 was used for all organs except the liver, which had a value of 3.5. When asked why the difference in cutoff values, Antoch said it was based on an analysis of the literature, which showed that FDG uptake is generally higher in the liver than the rest of the body organs.
Two radiologists evaluated the CT images, which determined whether lymph nodes were metastatic based on their size. Side-by-side images were evaluated by radiologists and nuclear medicine specialists on two different screens - CT on the right screen, PET on the left. The images were purposefully misregistered to ensure a degree of objectivity.
The same radiologists and nuclear medicine specialists reviewed the fused images one month after evaluating the side-by-side image analysis. Increased glucose metabolism was again used to determine pathology.
Researchers performed an analysis separately for the T-, N-, and M-stage and, in addition, they determined the impact on patient management that PET/CT had.
Histopathology was the standard of reference for 77 patients for the T-stage, 72 patients for the N-stage, and 57 patients for the M-stage. For all other patients, a mean clinical follow-up of 311 served as the standard of reference.
Fused PET/CT proved significantly more accurate in assessing the overall TNM stage compared with CT alone, PET alone, and side-by-side CT plus PET.
Of all 260 patients, 84 % were correctly staged with PET/CT, 76 % with side-by-side CT plus PET, 64 % with PET alone, and 63 % with CT alone.
Sensitivities and specificities for characterization of the N-stage were, respectively, 92% and 93% for PET/CT, 88% and 89% for CT plus PET, 85% and 88% for PET, and 64% and 83% for CT.
Sensitivities and specificities for assessment of the M-stage were, respectively, 94% and 97% with PET/CT, 92% and 96% with CT plus PET, 78% and 99% with PET, and 82% and 95% with CT.
"The most important point, however, is whether PET/CT impacted patient management," Antoch said. "Does it change patient therapy from palliative to curative, from curative to palliative? Or does it change the surgical approach from extended surgery to limited surgery?"
Combined PET/CT had an impact on the treatment plan in 17% of patients compared with PET alone, in 15% of patients compared with CT alone, and in 6% of patients compared with side-by-side CT plus PET.
Can MRI-Based AI Bolster Biopsy Decision-Making in PI-RADS 3 Cases?
December 9th 2024In patients with PI-RADS 3 lesion assessments, the combination of AI and prostate-specific antigen density (PSAD) level achieved a 78 percent sensitivity and 93 percent negative predictive value for clinically significant prostate cancer (csPCa), according to research presented at the Radiological Society of North American (RSNA) conference.
The Reading Room: Artificial Intelligence: What RSNA 2020 Offered, and What 2021 Could Bring
December 5th 2020Nina Kottler, M.D., chief medical officer of AI at Radiology Partners, discusses, during RSNA 2020, what new developments the annual meeting provided about these technologies, sessions to access, and what to expect in the coming year.
RSNA 2020: Addressing Healthcare Disparities and Access to Care
December 4th 2020Rich Heller, M.D., with Radiology Partners, and Lucy Spalluto, M.D., with Vanderbilt University School of Medicine, discuss the highlights of their RSNA 2020 session on health disparities, focusing on the underlying factors and challenges radiologists face to providing greater access to care.
New Interventional Radiology Research Shows Merits of Genicular Artery Embolization for Knee OA
December 3rd 2024In a cohort of over 160 patients with knee osteoarthritis (OA), including grade 4 in nearly half of the cases, genicular artery embolization led to an 87 percent improvement in the quality of life index, according to research presented at the
Siemens Healthineers Debuts New Photon-Counting CT Systems at RSNA
December 2nd 2024Debuting at the Radiological Society of North American (RSNA) conference, the new photon-counting computed tomography (PPCT) scanners Naeotom Alpha.Pro and Naeotom Alpha.Prime reportedly combine rapid scan times with high-resolution precision.