French firm biospace med acquires lateral, frontal radiographs simultaneously, creates reconstructions
Technology that 15 years ago led to a Nobel Prize in physics is today the cornerstone of a unique DR system that promises up to a 90% cut in radiation dose for body skeletal images compared with film systems. It produces both front and lateral views from head to toe in as little as 20 seconds .
The key is a particle detector invented by Nobel laureate Georges Charpak, adapted for medical radiography and built into the EOS low-dose 2D/3D orthopedic scanner by the French firm biospace med. Two slot-scanning digital detectors paired with x-ray tubes and mounted orthogonally on a vertical C-arm sweep the length of the patient in one continuous motion. Data can be displayed separately as lengthwise images, free from the distortion that can occur when conventional DR systems stitch together static images to cover a patient. Or, the frontal and lateral swipes of the body can be combined into a volumetric image.
Although the 2D/3D version is approved and marketed in the European Union and Canada, only the planar version is available in the U.S. But a 3D version is expected to pass FDA muster early this year. The strategy was to get the product on the U.S. market quickly to lay the groundwork for a big push once the 3D capability is through the FDA, according to Marie Meynadier, president and CEO of biospace med.
The EOS scanner can be set to sweep the entire length of the body or just part of it. In either case, the digital radiography device visualizes the bones and joints of the standing patient in a weight-bearing posture. This exposes balance and posture issues that can be valuable when planning surgery, she said. The system also automatically measures bone length and joint angles, quantifying these otherwise subjective analyses.
The combination of a continuous scan and Charpak’s ultrasensitive detector cuts dose by 50% to 90% compared with film images, depending on the patient, according to Meynadier.
“When we compare our doses with what you might get during a CT scan, we cut patient radiation exposure by a factor of 100 to 1000,” she said.
EOS’ ability to image the lower limbs and spine could prove especial ly important for the more than 900,000 scoliosis patients in the U.S. who must undergo periodic radiographic exams to monitor disease progression and gauge the effectiveness of treatment. Most of these patients are children who, because of the need for repeated exams, benefit from a device that minimizes radiation exposure.
At a half-million dollars, the device is priced higher than competing devices-and that’s only for the 2D configuration. Adding 3D will bump the price up a bit, although not a lot more, Meynadier said. She contends that the improvements in quality and the increased throughput possible with the device more than compensate for the higher price.
“At one of our investigational sites, we can put through about 50 spine patients in a morning,” she said.
Study Reaffirms Low Risk for csPCa with Biopsy Omission After Negative Prostate MRI
December 19th 2024In a new study involving nearly 600 biopsy-naïve men, researchers found that only 4 percent of those with negative prostate MRI had clinically significant prostate cancer after three years of active monitoring.
Study Examines Impact of Deep Learning on Fast MRI Protocols for Knee Pain
December 17th 2024Ten-minute and five-minute knee MRI exams with compressed sequences facilitated by deep learning offered nearly equivalent sensitivity and specificity as an 18-minute conventional MRI knee exam, according to research presented recently at the RSNA conference.
Can Radiomics Bolster Low-Dose CT Prognostic Assessment for High-Risk Lung Adenocarcinoma?
December 16th 2024A CT-based radiomic model offered over 10 percent higher specificity and positive predictive value for high-risk lung adenocarcinoma in comparison to a radiographic model, according to external validation testing in a recent study.