Demand for percutaneous vertebroplasty may be growing, but radiologists should not be offering the procedure unless they are properly trained and prepared, according to Prof. Afshin Gangi, a professor of radiology at the University Hospital of Strasbourg in France.
Demand for percutaneous vertebroplasty may be growing, but radiologists should not be offering the procedure unless they are properly trained and prepared, according to Prof. Afshin Gangi, a professor of radiology at the University Hospital of Strasbourg in France.
At an ECR 2008 foundation course on interventional radiology, Gangi used the interactive session to present a range of potential complications and explain exactly how they could be avoided. He urged audience members who were performing vertebroplasty-or contemplating doing so-to work under the guidance of high-quality x-ray fluoroscopy to ensure real-time feedback on their work.
He recommended that the injection rate should be relatively slow and halted at once should a leak be detected. If the leak persists after 30 seconds, the needle position should be changed. If this doesn't solve the problem, the procedure should be stopped.
When injecting bilaterally, both needles should be positioned and the cement injected before either is removed, Gangi said. Removal of the first needle prior to the second injection can lead to cement rising up the needle track.
Some patients with tumors may be undergoing radiofrequency ablation before vertebroplasty. It is important to allow the treatment area to cool before injecting the cement. Similarly, a minimum 30-minute wait is essential if vertebroplasty is following cryoablation to allow time for the ice ball to melt.
"You should not be aiming to be artistic, but aiming to do a good job. It's a complicated technique, so train and perform," Gangi said.
-By Paula Gould
New Study Examines Short-Term Consistency of Large Language Models in Radiology
November 22nd 2024While GPT-4 demonstrated higher overall accuracy than other large language models in answering ACR Diagnostic in Training Exam multiple-choice questions, researchers noted an eight percent decrease in GPT-4’s accuracy rate from the first month to the third month of the study.
FDA Grants Expanded 510(k) Clearance for Xenoview 3T MRI Chest Coil in GE HealthCare MRI Platforms
November 21st 2024Utilized in conjunction with hyperpolarized Xenon-129 for the assessment of lung ventilation, the chest coil can now be employed in the Signa Premier and Discovery MR750 3T MRI systems.
FDA Clears AI-Powered Ultrasound Software for Cardiac Amyloidosis Detection
November 20th 2024The AI-enabled EchoGo® Amyloidosis software for echocardiography has reportedly demonstrated an 84.5 percent sensitivity rate for diagnosing cardiac amyloidosis in heart failure patients 65 years of age and older.