German researchers have found that low-dose 64-slice CT colonography accurately detects colorectal polyps in a screening population. They also tested a new 3D visualization tool that enables simultaneous antegrade and retrograde views, significantly decreasing interpretation time.
German researchers have found that low-dose 64-slice CT colonography accurately detects colorectal polyps in a screening population. They also tested a new 3D visualization tool that enables simultaneous antegrade and retrograde views, significantly decreasing interpretation time.
Dr. Anno Graser, a radiologist at the University of Munich, presented the study on Tuesday during a scientific session at the RSNA meeting. The study is part of the Munich Colorectal Cancer Prevention Trial.
Graser and colleagues evaluated 300 asymptomatic subjects (154 women) who underwent same-day CT colonography and optical colonoscopy after complete bowel cleansing. Scans were acquired at 120 kV, 100 reference mAs (supine), and 40 reference mAs (prone). Online dose modulation was employed, and effective patient dose was calculated for all subjects. Radiologists used a primary 3D reading approach with 2D correlation.
Researchers divided the colon into six segments: cecum, ascending colon, transverse colon, descending colon, sigmoid colon, and rectum. Presence of polyps was rated according to size groups: small (5 mm or less), medium, 6 to 9 mm, or large (10 mm or greater). The median effective patient radiation dose was 4.2 mSv.
Overall, 138 adenomatous and 88 hyperplastic polyps in 112 patients were detected: 170 small, 38 intermediate, and 28 large. Sensitivity and specificity of CTC for adenomas were, respectively:
Per-patient sensitivities were 100%, 98%, and 80% for large, intermediate, and small polyps, respectively. Optical colonoscopy missed one large, two intermediate, and eight small polyps (sensitivities 96%, 95%, and 89.5%).
While CT colonography is accurate in detecting colorectal polyps, researchers cautioned that the detection of flat lesions remains problematic. And though video colonoscopy performed equally well, Graser said it is an imperfect standard of truth.
In another study, Graser and colleagues compared 3D CT colonography reading times using conventional 3D fly-through visualization (standard view) and a new 3D visualization tool (panoramic view) that enables simultaneous antegrade and retrograde views, unfolding the colon as the fly-through is being performed. Graser reported that reading times in the literature range from five to 53 minutes.
Researchers reviewed 200 CT colonography data sets from 100 patients from the ongoing single-institution trial comparing CT colonography and optical colonoscopy. Reading times for standard 3D interpretation with 2D for problem solving were documented. The same cases were interpreted again with the panoramic view without using the results from the standard view interpretation. Reading times for this technique were measured and documented.
The area of colonic mucosa that was visualized on a unidirectional fly-through from rectum to cecum was recorded for standard view and panoramic view. Differences in percentage of visualized colonic mucosa and reading times were tested for statistical significance using the t test.
Mean CTC interpretation time decreased from 18.5 minutes with 3D standard view software to 10 minutes using 3D panoramic view. The difference was significant (p
After unidirectional fly-through, the panoramic view had visualized an average of 95.5% of the colonic mucosa, whereas the standard view visualized only 79.4%, requiring an additional flight from rectum to cecum.
Researchers concluded that the new visualization technique significantly decreased interpretation time in 3D CT colonography. It visualizes the complete colonic mucosa in a unidirectional fly-through, whereas standard 3D tools require bidirectional fly-through to achieve complete visualization.
A participant questioned the potential learning curve for being able to look peripherally as well as straight ahead. Graser said that the overall fly-through speed will decrease because of the need to look peripherally. But the time savings are greater by not having to to fly-through bidirectionally.
"No one has the time to do two fly-throughs. So far, we've determined that this is a pretty nice tool to go through once," he said.
Can MRI-Based AI Bolster Biopsy Decision-Making in PI-RADS 3 Cases?
December 9th 2024In patients with PI-RADS 3 lesion assessments, the combination of AI and prostate-specific antigen density (PSAD) level achieved a 78 percent sensitivity and 93 percent negative predictive value for clinically significant prostate cancer (csPCa), according to research presented at the Radiological Society of North American (RSNA) conference.
The Reading Room: Artificial Intelligence: What RSNA 2020 Offered, and What 2021 Could Bring
December 5th 2020Nina Kottler, M.D., chief medical officer of AI at Radiology Partners, discusses, during RSNA 2020, what new developments the annual meeting provided about these technologies, sessions to access, and what to expect in the coming year.
RSNA 2020: Addressing Healthcare Disparities and Access to Care
December 4th 2020Rich Heller, M.D., with Radiology Partners, and Lucy Spalluto, M.D., with Vanderbilt University School of Medicine, discuss the highlights of their RSNA 2020 session on health disparities, focusing on the underlying factors and challenges radiologists face to providing greater access to care.
New Interventional Radiology Research Shows Merits of Genicular Artery Embolization for Knee OA
December 3rd 2024In a cohort of over 160 patients with knee osteoarthritis (OA), including grade 4 in nearly half of the cases, genicular artery embolization led to an 87 percent improvement in the quality of life index, according to research presented at the recent RSNA conference.
Siemens Healthineers Debuts New Photon-Counting CT Systems at RSNA