The era of 64-slice CT angiography as a tool to rule out cardiac catheterization in patients with an intermediate risk of coronary artery disease moved closer to reality at the RSNA meeting. A study confirming its superiority over dual-isotope SPECT for identifying CAD in these patients was reported in a Monday session.
The era of 64-slice CT angiography as a tool to rule out cardiac catheterization in patients with an intermediate risk of coronary artery disease moved closer to reality at the RSNA meeting. A study confirming its superiority over dual-isotope SPECT for identifying CAD in these patients was reported in a Monday session.
Dr. Tamar Gaspar of the Carmel Medical Center in Haifa, Israel, established the superiority of 64-slice CTA over SPECT by retrospectively examining 75 symptomatic patients who underwent both tests. SPECT analysis was performed using a 17-segment model, with perfusion defects graded visually on a four-point scale based on uptake and the likelihood of significant stenosis.
Patients with slightly reduced radiopharmaceutical uptake were then evaluated for the presence of greater than 50% coronary stenosis, signifying significant CAD, on multislice CT. Beta blockers were administered whenever required. Imaging was performed on a 64-slice Philips Brilliance 64 scanner, and the effective radiation dose averaged 12.9 mSv.
MSCT identified significant stenosis in one-third and excluded it in two-thirds of patients who showed grade 1 mild reversible perfusion defects on SPECT. Of the 79 coronary vascular territories shown to have mild reversible perfusion defects with SPECT, 25 were diagnosed as normal with 64-slice CT. Invasive x-ray coronary angiography performed on 21 patients confirmed 81% of the coronary CT findings.
CCT was responsible for four false positives. No false negatives were identified among the eight patients who underwent invasive angiography after a negative CT finding.
Unnecessary invasive procedures are avoided by applying CCTA to patients suspected of mild or intermediate disease, Gaspar said.
"If we can show normal coronaries on CT and take into account the high negative predictive value of CT for CAD, which is very well established, we won't have to refer these patients for invasive angiography, though they have had mild findings on SPECT," she said.
Can MRI-Based AI Bolster Biopsy Decision-Making in PI-RADS 3 Cases?
December 9th 2024In patients with PI-RADS 3 lesion assessments, the combination of AI and prostate-specific antigen density (PSAD) level achieved a 78 percent sensitivity and 93 percent negative predictive value for clinically significant prostate cancer (csPCa), according to research presented at the Radiological Society of North American (RSNA) conference.
The Reading Room: Artificial Intelligence: What RSNA 2020 Offered, and What 2021 Could Bring
December 5th 2020Nina Kottler, M.D., chief medical officer of AI at Radiology Partners, discusses, during RSNA 2020, what new developments the annual meeting provided about these technologies, sessions to access, and what to expect in the coming year.
RSNA 2020: Addressing Healthcare Disparities and Access to Care
December 4th 2020Rich Heller, M.D., with Radiology Partners, and Lucy Spalluto, M.D., with Vanderbilt University School of Medicine, discuss the highlights of their RSNA 2020 session on health disparities, focusing on the underlying factors and challenges radiologists face to providing greater access to care.
New Interventional Radiology Research Shows Merits of Genicular Artery Embolization for Knee OA
December 3rd 2024In a cohort of over 160 patients with knee osteoarthritis (OA), including grade 4 in nearly half of the cases, genicular artery embolization led to an 87 percent improvement in the quality of life index, according to research presented at the recent RSNA conference.
Siemens Healthineers Debuts New Photon-Counting CT Systems at RSNA
December 2nd 2024Debuting at the Radiological Society of North American (RSNA) conference, the new photon-counting computed tomography (PPCT) scanners Naeotom Alpha.Pro and Naeotom Alpha.Prime reportedly combine rapid scan times with high-resolution precision.